range | ComPact | |
---|---|---|
product name | ComPact NSX | |
range of product | ComPact NSX100...250 | |
device short name | VigiCompact NSX160F | |
product or component type | Circuit breaker with Vigi add-on | |
device application | Distribution | |
Number of poles | 4P | |
protected poles description | 3t 3t + N/2 4t | |
neutral position | Left | |
[In] rated current | 100 A at 40 °C | |
[Ue] rated operational voltage | 440 V AC 50/60 Hz | |
network type | AC | |
network frequency | 50/60 Hz | |
suitability for isolation | Yes conforming to EN/IEC 60947-2 | |
utilisation category | Category A | |
[Icu] rated ultimate short-circuit breaking capacity | 10 kA at 600 V AC 50/60 Hz conforming to UL 508 85 kA at 240 V AC 50/60 Hz conforming to UL 508 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 480 V AC 50/60 Hz conforming to UL 508 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 | |
Performance level | F 36 kA 415 V AC | |
trip unit name | Micrologic 2.2 | |
trip unit technology | Electronic | |
trip unit protection functions | LSoI | |
control type | Toggle | |
Circuit breaker mounting mode | Fixed |
[Ui] rated insulation voltage | 800 V AC 50/60 Hz | |
---|---|---|
[Uimp] rated impulse withstand voltage | 8 kV | |
[Ics] rated service short-circuit breaking capacity | 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 22 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 8 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 | |
mechanical durability | 40000 cycles | |
electrical durability | 7500 cycles at 690 V In 15000 cycles at 690 V In/2 20000 cycles at 440 V In 40000 cycles at 440 V In/2 | |
mounting support | Backplate | |
upside connection | Front | |
downside connection | Front | |
connection pitch | 35 mm | |
protection type | L : for overload protection (long time) So : for short time short-circuit protection with fixed delay I : for instantaneous short-circuit protection | |
trip unit rating | 100 A at 40 °C | |
Long-time pick-up adjustment type Ir (thermal protection) | Adjustable 9 settings | |
[Ir] long-time protection pick-up adjustment range | 40...100 A | |
Long-time protection delay adjustment type tr | Fixed | |
[tr] long-time protection delay adjustment range | 11 s at 7.2 x Ir 16 s at 6 x Ir 400 s at 1.5 x Ir | |
thermal memory | 20 minutes before and after tripping | |
Short-time protection pick-up adjustment type Isd | Adjustable 9 settings | |
[Isd] Short-time protection pick-up adjustment range | 1.5...10 x Ir | |
Short-time protection delay adjustment type tsd | Fixed | |
Instantaneous protection pick-up adjustment type Ii | Fixed | |
[Ii] instantaneous protection pick-up adjustment range | 1500 A | |
earth-leakage protection | With | |
earth-leakage add-on module name | MH | |
earth-leakage protection class | Class A | |
Earth-leakage protection sensitity adjustment type IΔn | Adjustable 5 settings | |
[IΔn] earth-leakage protection sensitivity adjustment range | 0.03…10 A | |
Earth-leakage protection time delay adjustement type Δt | Adjustable 4 settings | |
Neutral protection settings | 0.5 x Ir (3t + N/2) 1 x Ir (4t) No protection (3t) | |
Number of slots for electrical auxiliaries | 6 slot(s) | |
local signalling | Flashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload | |
Width (W) | 140 mm | |
Height (H) | 236 mm | |
Depth (D) | 86 mm | |
net weight | 2.6 kg |
standards | EN/IEC 60947 | |
---|---|---|
product certifications | CCC EAC Marine | |
overvoltage category | Class II | |
electrical shock protection class | Class II | |
pollution degree | 3 conforming to IEC 60664-1 | |
IP degree of protection | IP40 conforming to IEC 60529 | |
IK degree of protection | IK07 conforming to IEC 62262 | |
ambient air temperature for operation | -25…70 °C | |
ambient air temperature for storage | -50…85 °C | |
relative humidity | 0…95 % | |
operating altitude | 0...2000 m without derating 2000 m...5000 m with derating |
Unit Type of Package 1 | PCE | |
---|---|---|
Number of Units in Package 1 | 1 | |
Package 1 Weight | 3.841 kg | |
Package 1 Height | 14.5 cm | |
Package 1 width | 19 cm | |
Package 1 Length | 29.19 cm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | REACh Declaration | |
EU RoHS Directive | Compliant EU RoHS Declaration | |
Mercury free | Yes | |
RoHS exemption information | Yes | |
China RoHS Regulation | China RoHS declaration Product out of China RoHS scope. Substance declaration for your information | |
Environmental Disclosure | Product Environmental Profile | |
Circularity Profile | End of Life Information | |
PVC free | Yes |
Warranty | 18 months |
---|